• Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor
  • Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor
  • Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor
  • Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor

Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor

Theory: Voltage Relay
Usage: General Purpose
Phase: 1
Electricity Type: Dc
Number of Pole: 1
Load: High Power Relay
Samples:
US$ 21.00/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Zhejiang, China
to see all verified strength labels (22)

Basic Info.

Model NO.
ADH100
Protective Characteristics
Sealed Relay
Action Principle
Electromagnetic Type
Size
54.7*49.2*62mm
Type
Electric Parameter Relay
Protect Feature
Sealed
Coil Power
2W
Contact Load
High Power
Feature
High Voltage DC Relay
Weight
190g
Contact Form
1h
Name
Adh High Voltage DC Relay
Rated Voltage
12-900V
Coil Rated Voltage
12V,24V
Temperature Range
-40ºC-85ºC
Quality Control
ISO9001
Transport Package
Standard Exporting Packages
Trademark
Aokaii
Origin
Zhejiang, China

Product Description

Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor

12V 24V Standard type high voltage relay for DC/AC inverter 100 amp energy saving dc contactor 

        Brand:AK/AoKai

 

        Name:ADH High-voltage DC Contactor

 

        Model:ADH100AP

 

        Rated Voltage:DC12/24/48V

 

        Rated Current:100A,DC12-900V

 

        Dimension:54.7*49.2*62(mm)

 

        Weight:About 190g

    Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor
Product Features:1,Nonpolarity-The connection of contact and coil need to be nonpolarity;2,Epoxy Sealant-Sealed by epoxy resin. It can work in the hostile environment,Coil and contact cannot be oxidized and polluted;3,Efficient Coil - Optional built-in energy-saving coil, retentive power is only 2-2.3W, counter electromotive force is 0V.; 4,ROHS authentication is totally meet the requirement of ROHS, It is benefit to body health and the environment protection.;5,Compare to the similar products, this product is smallest and ligtest.;6,The joint way of the coil is very convenient;;7,The coil has no counter-force of electromagnetism.
Product Application:ADH Series HVDC Contactor  are widely used in Electric vehicles, hybrid electric vehicles, fuel cell cars, construction machinery, photovoltaic power generation, wind power, battery charging and discharging system, dc voltage power supply control, and other areas of the dc high voltage.
 
ADH Application

Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor

 

Product Show

 Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor

Model Implication                                                                                                                                              

 

Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor

 

   

Technical Parameters

Electrical specification

Insulation Resistance Between Contacts 1000MΩ(1000VDC)
Between Contacts and Coil 1000MΩ(1000VDC)
Between Contacts and Shell 1000MΩ(1000VDC)
Dielectric strength Between Contacts 4000V rms
Between Contacts and Coil 4000V rms

Physical specification

Impact   Stability 196m/s2(20G)
 Strength 490m/s2(50G) 
  Vibration 10-500Hz 98m/s2(10G) 

Life expectancy

Mechanical life 1,000,000 times
Impedance load life(Switch)

20,000times(50A 450VDC)

20,000times(-50A 450VDC)

Capacitive load life(Just closed) 50,000times(100A 1ms)
60times(250A 1ms)
10times(400A 1ms)

Main contact parameters

Contact form 1SH  Leading-out M4 Internal thread 
Contact resistance  0.5mΩ (50A) Rated load voltage 12-900VDC 
Maximum switching surrent 500A 320VDC(≥1times)   Maximum switching power 160KW 
Rated load current 50A  Rated Electric life 20,000times 
Min Load 1A 12VDC  Standards for electric current(10mm2Line)   50A
Short time overload  current(10mm2@40)   75A 15min,100A 3min,150A 30s

Coil Parameters

Parameters Standard type voltage
12VDC 24VDC
 Work voltage 18-32  
 Max voltage 36  
 Action voltage 7-8  
 Release voltage 5-6  
 Coil resistance 4.7  
 Min start current(A) 1.5  
 Transient surge current(A) 2.5(0.1s)  
 Average holding current(A) 0.18(@12V)  
 Steady state Power(W) 2-2.3  
 Actuation time(ms) ≤20  
 Release time(ms) ≤10  
 Bounce time(ms) ≤5

Conditions of usage

Operate temperature  -40~85
 Operating Humidity  5~95%RH
 IP Grade  IP67
 Dimension(W×H×D,mm)  54.5×49.2×62
 Weight(g)  190g

Re:If you need other rated voltage, can be a special order.

 
Life of the graph

Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor

Re:
1.Resistive load, including the maximum load inductance300μH;
2. According to extrapolated, it is recommended to do experiments for different situations;
3. After life time, diaelectric strength dropped lower than 100MΩ at 1000VDC;
4. The biggest and current.

 

 
Coil schematic

 

Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor

 

Re:A1, A2 as the load; 1, 2 for the coil end; Load and coil has no polarity.

 
Installation Diagram

 Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor

Notes                                                                                                                                                                 
1. Under the resistance load, the rated parameters of the main contact is applicable. If inductive load is adopted and L/R>1ms, the inductive load need to have an protective unit of inrush current in parallel, and also spare room needs to be considered in the designation.
2. The coil and the contact of the contactor coil need to be continuously charged with electricity when full loaded. The power need to be connected when cut off. Because of the rise of the temperature, the coil resistance is rising, and the pull-in voltage is also risen. The following measure should be taken: lowering the load voltage and limiting the power-on time.

3. The power of drive circuit of the contact coil must be greater than the coil power of the products. Otherwise, the normally usage of high voltage dc contactor will be influenced.


4. The contactor with energy saving board, when connected after 0.15s, the coil starts to switch automatically. Please do not repeat to turn on and turn off. Otherwise, the contactors maybe broken.


5. Working Life: ADH series contactors are high voltage switch. It may lost its switch function when in the breakdown mode. Therefore, please do not use it when the condition is not suitable to the contactors. When the working life is almost there, please to change it in time in order not to flame the parts around. The circuit diagram should be well-designed in order to switch off within 1 second.


6. Internal Gas and Life: ADH series contactors adopt pressurized cabin contact. The cabin is filled with gas. The life of the gas is decided by the cabin temperature of the contact. Therefore, the environment temperature should be ensured between -40 and +85.


7. Please do not use it where the magnetic field is high or near the thermal radiation.


8.To ensure the main power line is closest to the terminal of the contactors. The plain washer, spring washer, nut and screw need to be installed tightly. The incorrect connection order may cause serve overheating and the fusion of the insulating layer.


9. In order not to break the products, the tightening torque of the nuts and screws of the contactors needs to be controlled under the following range. 

(1) Terminals: :
M4 screw (ADH series 50A): 2~3N·m;

(2) Mounting Hole:2~3.5N·m.
Please avoid adhering the oil on the terminal.
Please use the following connecting wire. Otherwise, the unusual overheating will be caused:
ADH-50A: nominal area should be above 15mm;

Please do not use the contactor when it is dropped unexpectedly or over-shocked.

Hot sale products                                                                                                                                              
Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor
 
Conventional Templa

Aokai Standard Type High Voltage Relay for DC/AC Inverter 100 AMP Energy Saving DC Contactor

Advantages

  1. Small Orders Accepted

  2. Quality Approvals

  3. Prompt Delivery

  4. Packaging

  5. Price is good

  6. International Approvals

  7. Other specification can be customized upon different requirements. 

  Energy Saving Type Using in Golf Cart ADH50 50A High Voltage DC Relay

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now