Electricity Type: | DC |
---|---|
Number of Pole: | 1 |
Phase: | 1 |
Main Circuit Rating Voltage: | 60VDC |
Main Circuit Rating Current: | 400A |
Type: | Dc Contactors |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Elevator Motor DC Albright Contactor 400A, 12V, 24V or 48V Coil Voltage (SW200)
Brand: AK/AOKAI
Name: DC Contactor
Model: ASW400/SW200
Rated Voltage: DC12V-120V
Rated Current:400A
Dimension:73*57*156(mm)
Weight: About 1330g |
SPECIFICATION
Coil Rated Voltage | DC12V, 24V, 36V, 48V.etc. |
Main Circuit Rated Current (A) | 400A |
Main Circuit Contact Voltage Drop Of (load:100A) |
less than 80mV |
Under (20±5), Cooling Pull-in Voltage | less than 70% |
Under (20±5), Cooling Release Voltage | ≥5%, ≤40% |
Acceptable Fluctuation Range of Coil Voltage | ±20% |
drop-out time | ≤30ms |
pull-in time | ≤20ms |
The Max Disconnecting Time of Contacts | ≤5ms |
Insulation Resistance | ≥50MΩ |
Dielectric Strength | 50Hz/60Hz 1000VAC/1min |
Overload Current | ≤7Ie, ≤1s |
Coil Consumption (W) | ≤15.0W |
Electrical Life | 20000 times |
Mechenical Life | 300 Thousand times |
Working Mode | Continuous or intermittent |
Contacts Type | 1 NO and 1 NC |
Contact Material | AgCdO / AgCuO |
Auxiliary Contact Rated Load (Optional Parts) | 2A/48VDC, 5A/24VDC |
Technical Standard | GB14048.4-2010 |
USAGE ENVIRONMENT
Altitude | ≤2Km | Amblent temperature | -25~+55 |
International protection | IP50 | Installation type | III |
Way to install | Any | Vibration | 2.5g(5~50)Hz |
Impact | 50g,11ms(Half-sine wave) |
SCHEMATIC DIAGRAM
INSTALLATION DIAGRAM
Suppliers with verified business licenses